Flat cables are manufactured from EC
grade (Electrolytic Grade) Copper Conductor, Annealed and concentrically bunched
to ensure uniformity, circular cunstruction, flexibility & uniform
resistance.
Each bunch of copper conductor
is insulated with PVC compound especially
formulated and manufactured in-house
to make cores. Parallel laid cores are
sheathed with abrasion resistant PVC
compound impervious to water, grease,
oil & salinity of water.
AS per specific requirement, we provide
EPR & TPR insulated & sheathed submersible cables.
| Conductor |
Insulation |
Sheath |
Overall
Dimensions |
Conductor
Resistance @ 20°C (Max) ohms/km. |
Current
Carrying Capacity @20°C (Amps.) |
Area Sq.mm. |
No.
of Strands/Dia. Mm |
Thickness
(Nom)Mm |
Thickness
(Nom)Mm |
Width
(Approx) “W” mm |
Height
(Approx) “W” mm |
1.0 |
14/0.3* |
0.6 |
0.9 |
10.5 |
5.0 |
18.10 |
11 |
1.5 |
22/0.3* |
0.6 |
0.9 |
11.5 |
5.4 |
12.10 |
14 |
2.5 |
36/0.3* |
0.7 |
1.0 |
14.0 |
6.4 |
7.41 |
18 |
4.0 |
56/0.3** |
0.8 |
1.0 |
16.5 |
7.4 |
4.95 |
26 |
| Note
: |
The
diameter of strand mentioned is nominal diameter to
satisfy the requirements of conductor resistance as
per IS:8130:1984
* As per conductor class 2 of IS:8130:1984
** As per conductor class 5 of IS:8130:1984 |
| Conductor |
Insulation |
Sheath |
Overall Dimensions |
Conductor
Resistance @ 20°C (Max) ohms/km. |
Current
Carrying Capacity @20°C (Amps.) |
Area Sq.mm. |
No.
of Strands/Dia. Mm |
Thickness
(Nom)Mm |
Thickness
(Nom)Mm |
Width
(Approx) “W” mm |
Height
(Approx) “W” mm |
6.0 |
84/0.3 |
1.0 |
1.15 |
18.7 |
7.9 |
3.30 |
31 |
10.0 |
14/0.3 |
1.0 |
1.40 |
23.7 |
9.9 |
1.91 |
42 |
16.0 |
226/0.3 |
1.0 |
1.40 |
28.0 |
11.4 |
1.21 |
57 |
25.0 |
354/0.3 |
1.2 |
2.00 |
35.5 |
14.7 |
0.780 |
72 |
35.0 |
495/0.3 |
1.2 |
2.00 |
39.5 |
16.2 |
0.554 |
90 |
50.0 |
703/0.3 |
1.4 |
2.20 |
45.5 |
18.3 |
0.386 |
115 |
70.0 |
360/0.5 |
1.4 |
2.20 |
51.0 |
20.0 |
0.272 |
143 |
95.0 |
475/0.5 |
1.6 |
2.40 |
60.0 |
23.5 |
0.206 |
165 |
DEWATERING PUMP CABLES
Heavy duty cables are needed for
applications like sewage, slurry, and dewatering pumps.
For the above
applications sheathing must be capable to with stand abrasion,
prevent in grease of water along the interstices of the cable & be
resistant to chemicals & acidic fluids.
Three & Four core double sheathed
cables are ideally suited for the above applications.
| Conductor |
Radial
Thickness Insulation
mm |
Thickness Inner
Sheath |
Thickness Outer
Sheath |
Overall Diameter
Approx. |
Sq.mm. |
Size/nos |
3
Core
mm |
4
Core
mm |
3Core
mm |
4Core
mm |
3
Core
mm |
4
Core
mm |
1.5 |
30/0.25 |
0.6 |
1.0 |
1.0 |
1.2 |
1.2 |
10.8 |
12.0 |
2.5 |
50/0.25 |
0.7 |
1.0 |
1.0 |
1.2 |
1.2 |
13.2 |
13.8 |
4.0 |
56/0.3 |
0.8 |
1.0 |
1.0 |
1.2 |
1.4 |
14.2 |
15.5 |
6.0 |
84/0.3 |
0.8 |
1.0 |
1.0 |
1.4 |
1.4 |
16.5 |
18.5 |
10.0 |
140/0.3 |
1.0 |
1.0 |
1.0 |
1.4 |
1.4 |
19.1 |
22.0 |
16.0 |
226/0.3 |
1.0 |
1.0 |
1.0 |
1.4 |
1.4 |
23.5 |
25.0 |
25.0 |
354/0.3 |
1.2 |
1.0 |
1.0 |
1.6 |
1.6 |
28.5 |
31.0 |
35.0 |
495/0.3
|
1.2 |
1.0 |
1.0 |
2.0 |
2.0 |
30.5 |
32.8 |
Note
: While Placing your Inquiry/Order Please specify
a). Packing length.
b). Total requirment
|